motor, it is necessary to use locking nuts (do not use split lock washers) and tighten the bolts evenly to the recommended torque ratings. Never reinstall used fasteners as they may fail under load. Check the bolts for security after a few hours of operation.It is imperative that the eccentric weights at both ends of the shaft are adjusted identically: “mirror images of each other.” When adjusting the eccentric weights, use the least amount of amplitude and force to move your material.
This will provide longer motor life.See the “Eccentric Weight Adjustment”section.
The VB series electric vibrators are supplied with a terminal block to provide safe and secure lead attachment. Wiring of these motors must be done in accordance with the National Electric Code. See Figures 2 through 6 for wiring diagrams. Each motor is supplied with a wiring diagram inside the terminal box.
Always use closed loop wire connectors only with crimped or soldered terminal ends on cable leads. See Figure 1 for the correct technique for assembling the wire connectors. Reinstall the foam rubber blocks supplied in the junction box on top of the cable leads.When wiring the VB series electric vibrators, always use the ground connection.